SZI Series Blind-free Safety Light Curtain Safety Grating, Cross Section Area: 30*30 mm
Overview
The SZ series safety light curtains are extremely cost-effective and are the perfect solution for hazardous point protection and one-sided access protection, helping users to easily achieve safety protection from start to finish.
The combination of safety and efficiency - the most practical
In all industries, the cost-effective SZ series of safety light curtains guarantee the safety of personnel and machines and systems (such as those used in processing machines of various sizes).
Typical application areas include:
■ Machine tool industry
■ Press industry
■ Automotive industry
■ Fixture equipment
■ Handling and storage system
■ Welding equipment
■ Consumer goods and packaging industry
■ Regional protection
■ Test equipment
■ Food manufacturing
■ Electronic equipment industry
■ Thermoforming machine industry
■ Medical equipment industry
■ Robot manufacturing industry
SZC Universal Safety Light Curtain Safety Grating - Technical Specifications Overview
■ Level 2 security protection
■ No blind zone / blind zone Optional
■ Resolution: 10/15/20/30/40/60 mm
■ Protection zone height: 60 mm to 2000 mm
■ Automatic range measurement of protection zone width up to 5m
■ Ambient operating temperature: –30°C to +65°C
■ Enclosure protection rating: IP 65
■ M12 aviation plug
SZ basic safety light curtain is widely used in various safety applications
For extremely limited space: continuous protection zone
The SZI series of safety light curtains form a high-resolution continuous protection zone that covers the entire enclosure up to the end of the enclosure, minimizing the safety distance required for machine integration. In addition, the SZI series of safety light curtains can be protected up to 3m in height. As a result, the product allows distances above and below the safe area to be much smaller than existing safety standards. The SZI series of safety light curtains also reduce the safety distance between the operator and the danger point, effectively increasing production efficiency.
Sturdy casing: SZA series safety light curtains are made of high-strength aluminum profiles, which ensure the safety light curtain is resistant to bending and impact.
Power-on: No security is required without any setup, and work and troubleshooting are fast.
Fast commissioning with LED indicators: The SZ Series Safety Light Curtains perform all basic functions without pre-configuration and require no software to complete the commissioning process. In addition, some models are equipped with integrated LED indicators and diagnostics, which effectively reduces commissioning time.
Plug-and-play maintenance and replacement: The SZ Series Safety Light Curtains require quick maintenance without configuration or wiring. All products feature an exquisite bracket design and standardized M12-4 pin plug technology, simplifying the replacement process for each device. In addition, bright LEDs continuously provide status information for all processes.
Safety light curtain installation instructions
Note: The installation position refers to the position of the safety light curtain relative to the upper and lower die of the machine. That is, under the premise of ensuring the safety distance, the last light of the safety light curtain shall not be higher than the lower edge of the lower die, and the upper beam shall not be allowed. Below the upper edge of the upper die. This involves the safety light curtain protection height
Calculation of safety distance
In order to ensure the operator's personal safety, the installation position of the safety light curtain must meet the requirements of the safety distance. Otherwise, there is still the possibility of an accident.
■ Safety distance refers to the minimum distance between the light curtain and the cutting edge of the die. The calculation method should be calculated according to the formula of the brake method of the press, or refer to the following table.
■ For presses where the slider can be braked at any position of the stroke, the safety distance:
Ds=1.6(T1+T2)
Where: Ds - safety distance, in meters (m)
1.6 - Stretching speed of the hand, in meters per second (m/s)
T1 - response time of safety light curtain, 0.02 seconds (s)
T2——The braking time of the equipment, that is, the time from the start of braking to the stop of the slider, in seconds (s), measured from the actual braking condition
■ For presses where the slider cannot be braked at any position of the stroke, the safety distance:
Ds=1.6Ts
Where: Ds - safety distance, in meters (m)
1.6 - Stretching speed of the hand, in meters per second (m/s)
Ts - the time from when the person leaves the light curtain (that is, the slider is allowed to start) until the device slider reaches the bottom dead center, that is, the down travel time of the slider, in seconds (s), can be calculated according to the following formula or actually measured:
Ts=(1/2+1/N)T
Where: N - the number of engagement slots of the clutch
Tn - the time the crankshaft makes one revolution, in seconds (s)
Wiring
Optical synchronization wiring Line synchronous wiring Relay output wiring
Interpretation of indicator status
Output form
|
Light curtain state
|
Receiver indicator
|
Output transistor state
|
NPN Type
|
Pass light
|
Bright green light
|
ON
|
0.3WOutput level≤1V
|
Shading
|
Bright red light
|
OFF
|
OPENLeakage current≤2mA
|
malfunction
|
Flashing red light
|
OFF
|
OPENLeakage current≤2mA
|
PNP Type
|
Pass light
|
Bright green light
|
ON
|
0.3W Output level≤1V
|
Shading
|
Bright red light
|
OFF
|
OPEN,DO0V Ground resistance10K
|
malfunction
|
Flashing red light
|
OFF
|
OPEN,DO0V Ground resistance10K
|
Technical Parameters
Product picture
|
|
Light curtain type
|
SZI
|
Section size
|
30*30*L mm
|
Enclosure rating
|
IP65
|
Supply voltage
|
DC12V-36V±10%
|
Response time
|
≤10ms
|
Signal output
|
NPN/PNP/Relay
|
Synchronization type
|
Optical synchronization / line synchronization
|
Number of beams
|
4-500bundle
|
Optical axis spacing
|
10mm/15mm/20mm/30mm/40mm/60mm
|
Protection height
|
60-3000mm
|
Protection distance
|
0.1-3 m
|
Light curtain form
|
Opposite type
|
Anti-interference ability
|
10000Lux
|
Shape material
|
Aluminum alloy
|
Circuit protection
|
Reverse protection / output short circuit protection
|
Power consumption
|
3-8W
|
Operating temperature
|
-15℃--65℃
|
Ambient temperature
|
20C,RH≤85%
|
Dielectric strength
|
DC30V.5A
|
Insulation resistance
|
>100 MΩ
|
certified product
|
CE ROHS
|